Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)

Product Details
Customization: Available
Customized: Non-Customized
Standard: Ce, FDA, ISO13485, SGS
Gold Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Spanish; Russian
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
to see all verified strength labels (24)
  • Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)
  • Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)
Find Similar Products

Basic Info.

Model NO.
BJ2103
Material
Steel
Usage
Orthopedic
Color
Slivery
Packing Way
Carton or Disinfection Box
Main Material
Stainless Steel, Aluminium Alloy
Name
Medical Surgical Drill Adapter
Use for
Contect with Multi Drill to Surgery
Application
Orthopedic
Feature
Reusable
Group
Adult
Medical Device Regulatory Type
Type 2
Medical Devices Reg./Record No.
Hxzz20162100264
Transport Package
Carton
Specification
CE, FDA, ISO, SGS
Trademark
Bojin or OEM
Origin
Shanghai, China
HS Code
90189090
Production Capacity
12000 Sets/Year

Product Description


Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)
Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)
Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)
Parameter:
Electric Handpiece: BJ2100 
Electric: Yes
Multifunctional:  Yes
Weight (with battery):  ≤1000 Grams
Speed: 0-15000 rpm 
Power source: Battery
Sterilizable: Autoclavable
Battery: BJ1001
Technology:  Ni-Mh 
Insert/detachment method: The telescopic
The blocking mechanism:  Yes
Autoclavable Aseptic Transfer Kit: Yes
Run time with battery: 30-40 min
Battery Charger  BJ1002-4 
Simultaneously charged batteries:  4
Battery charge status: Indicator light 
Sagittal saw attachment: BJ2101
Oscillations (osc/min)  0-15000
Operation(V) voltage  14.4
Sterilization 135°C
Noise(db)  ≤75
Bone drill attachment: BJ2102/BJ2102SAO
Speed(r.p.m)  0-1000
Torque(Nm) 2.9
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤40
Canulate drill attachment: BJ2103/BJ2103B/BJ2103D
Speed(r.p.m)  0-630
Torque(Nm) 3.3
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤40
Cranial drill attachment: BJ2104
Speed(r.p.m)  0-1000
Torque(Nm) 2.9
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤40
Cranial bur attachment: BJ2105
Speed(r.p.m)  0-40000
Sterilization 135°C
Noise(db)  ≤40
Sternum saw attachment: BJ2106
Oscillations (osc/min)  0-15000
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤70
Acetabulum reaming drill attachment: BJ2107/BJ2107B/BJ2107D
Speed(r.p.m)  0-280
Torque(Nm) 7.8
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤40
Reciprocating saw attachment BJ2109
Oscillations (osc/min)  0-15000
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤70
Torque limiter attachment BJ2110/2111
Torque(Nm) 4NM/1.5NM
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤40
TPLO saw attachment BJ2112
Oscillations (osc/min)  0-15000
Operation(V) voltage 14.4
Sterilization 135°C
Noise(db)  ≤70

Notes:
1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the 
    temperature is over 135 ° C ,the motor will be damaged.
2.Normal bone drill can only hold drill bits less than 6mm,acetabulum 
    reaming drill with big torque,rpm is around 300,canulate drill is used 
    with nail or K wire ,rpm is around 600.
3.The battery need to be get out of the pwer tool after surgery. Otherwise 
    the small automatic discharge of the electric will make the life of the 
    battery short.
4.The battery cannot be sterilized ,it is not autoclavable.
5.The cranial bur must be washed right after the surgery by purger in 
    order to aviod the blood stick in the bur,then we should make it dry.
6.The battery space in the handpiece of the tool should not have any 
    water,after sterilization.
7.The cranial bur blade is made of medical stainless steel,in order to 
    avoid broken,so it is flexible and not very hard,it is easy to be attrite, 
    we suggest each blade only use for 1 surgery.

Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)
                                                      About us
          Established in 1993 and headquartered in Shanghai, Bojin, as an advanced orthopedic equipment
manufacturer and solutions provider, Bojin focuses on the development and marketing of orthopedic-purpose
motor products, X-ray imagescopes, treatment apparatus, and supporting surgical tools/parts. It has more than
one hundred types of orthopedic products under 8 series, which have received QC certification of 3C, ISO9001,
ISO13485, CE of the EU, and FDA Registry 3008787426. Its mission is to satisfy the needs of patients and
medical care with innovative high-tech products and therefore become a promoter of people's orthopedic health.
It has built a healthy sales and services network thanks to its 200 dedicated employees in the marketing
companies or teams in more than 4countries and regions across North America, Europe and Asia. Its products
are used in more than 60 countries and, in particular, in more than 20000 Chinese medical institutions 70%
of which are 3A-rated hospitals.

Orthopedic Adapter for Orthopedic Medical Surgical Drill (system 2000)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier